Ultra 6 Ultrasonic Liquids flowmeter

 
FMC Ultrasonic liquid flowmeter Ultra 6

General Description

The Smith Meter® Ultra6™ Liquid Flowmeter is a six path ultrasonic meter with a Signal Processing Unit (SPU) for custody transfer of refined petroleum products and crude oils. The Smith Meter Ultra Series is the newest entry in the FMC Technologies Measurement Solutions family of high accuracy metering products which also includes the Ultra4 for high accuracy liquid measurement applications and MPU 1200, 800, 600 and 200 gas ultrasonic flow meters. The Ultra6 utilizes the same technologies as the world leading MPU 1200 gas ultrasonic meter, in terms of path configuration, electronics and signal processing.

FEATURES

  • Low Pressure Drop - Drop is the same as an equal length of straight pipe
  • Low Maintenance - No moving parts that need replacement due to wear, especially beneficial in severe operating environments
  • Ideal for Problematic Applications - Non-intrusive parts help avoid product build up on equipment
  • Operational Flexibility - Bi-directional flow reduces time required to redirect product flow
  • Custody Transfer Accuracy - Meets or exceeds custody transfer requirements worldwide
  • Real Time Diagnostics - WinScreen Software provides real-time logs, trends, signal performance and parameter reports for operation, diagnostics and maintenance
  • Reciprocity - Exclusive transducer and electronic design that virtually eliminates zero flow offset and drift to provide long-term measurement stability independent of pressure, temperature, and transducer aging
  • Low Frequency Transducer - Alternate transducer available on 12" and higher sizes to extend viscosity capabilities
  • Field-Proven Electronics - The same electronic processor and rugged packing as the FMC Technologies MPU Series gas ultrasonicmeters which have been proven in the world's harshest field environments
  • In-line Transducer Replacement - Designed so there is no need for special tooling or process shutdown to replace a transducer

SPECIFICATIONS

Sizes 6", 8", 10", 12", 14", 16", 18", 20", larger sizes available on demand
Flow Range 25 m³/h up to 7950 m³/h (size-dependend)
Repeatability ± 0.02%
Linearity ± 0.15% over the normal flow range
Viscosity Range 0.5cps upt to 2050cps (size-dependend)
Max. Operating Pressure 153bar
Operating flow temperatures -50°C - 120°C
Operating ambient temperature -40°C - 60°C